Shipping Estimate
USA
- USA
- CAN
- USA
- CAN
Ships within 48 hours · Estimated delivery Jul 11 - Jul 16
For Your Every Summer RSVP, with Code: SUMMER15
Description
Human LTbR ELISA KitProduct Specification Usage Required experimental equipment: 1. Microplate reader (450nm) 2. High precision pipettes and pipette tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37C incubator 4. Distilled or deionized water Sample preparation and requirements: Tissue homogenization: Rinse the tissue with pre chilled PBS (0. 01M, pH 7. 4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh and
Product Specification
| Usage | Required experimental equipment: 1. Microplate reader (450nm) 2. High-precision pipettes and pipette tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL 3. 37°C incubator 4. Distilled or deionized water Sample preparation and requirements: Tissue homogenization: Rinse the tissue with pre-chilled PBS (0.01M, pH 7.4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh and mince the tissue. Add the minced tissue to the appropriate volume of PBS (generally a 1:9 weight-to-volume ratio, e.g., 1g of tissue sample to 9mL of PBS. The specific volume can be adjusted according to experimental needs and recorded. It is recommended to add protease inhibitors to the PBS) in a glass homogenizer and grind thoroughly on ice. To further lyse tissue cells, the homogenate can be sonicated or repeatedly frozen and thawed. Finally, centrifuge the homogenate at 5000×g for 5-10 minutes, and collect the supernatant for analysis. Cell Lysis Buffer: Adherent cells should be gently washed with pre-chilled PBS, then trypsinized and harvested by centrifugation at 1000×g for 5 minutes. Suspension cells can be harvested directly by centrifugation. Collected cells should be washed three times with pre-chilled PBS and resuspended in 150-200 μL of PBS per 1×10^6 cells (it is recommended to add protease inhibitors to the PBS; if the cell count is very low, reduce the PBS volume appropriately). Disrupt the cells by repeated freezing and thawing or sonication. Centrifuge the extract at 1500×g for 10 minutes at 2-8°C, and collect the supernatant for analysis. Other biological fluids: Centrifuge at 1000xg for 20 minutes, remove the supernatant, and test. Pre-test preparation: 1. Remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature. 2. Prepare the standard gradient working solution: Add 1 mL of universal diluent to the lyophilized standard, let it stand for 15 minutes to completely dissolve, then gently mix (concentration is 20 ng/mL). Then dilute to the following concentrations: 20 ng/mL, 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.3125 ng/mL, and 0 ng/mL. Serial dilution method: Take 7 EP tubes and add 500 μL of universal diluent to each tube. Pipette 500 μL of the 20 ng/mL standard working solution into the first EP tube and mix thoroughly to make a 10 ng/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube serves directly as a blank well; there is no need to aspirate the liquid from the penultimate tube. See the figure below for details. 3. Preparation of Biotinylated Antibody Working Solution: 15 minutes before use, centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration using universal diluent (e.g., 10µL concentrate + 990µL universal diluent). Prepare immediately before use. 4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately. 5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing). Procedure: 1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C. 2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.) 3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes. 4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used). 5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes. 6. Washing: Discard the liquid and wash the plate five times as in step 4. 7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes. 8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm. Calculating experimental results: 1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis. 2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor. |
|||||||||||||||||||||||||||||||||
| Theory | This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with a Lymphotoxin Beta Receptor (LTbR) capture antibody. After incubation and washing, the sample is developed using the substrate TMB. TMB is converted to blue by peroxidase (HRP) catalysis and to yellow by acid. The intensity of the color is positively correlated with the amount of Lymphotoxin Beta Receptor (LTbR) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration. | |||||||||||||||||||||||||||||||||
| Source | Human | |||||||||||||||||||||||||||||||||
| Synonym | Human Lymphotoxin Beta Receptor ELISA Kit | |||||||||||||||||||||||||||||||||
| Detection Type | Double antibody sandwich method | |||||||||||||||||||||||||||||||||
| Composition |
|
|||||||||||||||||||||||||||||||||
| Background | Lymphotoxin beta receptor (LTbR), also known as tumor necrosis factor receptor superfamily member 3 (TNFRSF3), is a cell surface receptor for lymphotoxins involved in apoptosis and cytokine release. The protein encoded by this gene is a member of the tumor necrosis factor (TNF) receptor family. It is expressed on the surface of most cell types, including epithelial and myeloid cells, but not on T and B lymphocytes. LTbR not only helps trigger apoptosis but also leads to the release of the cytokine interleukin-8. Overexpression of LTbR in HEK293 cells increases IL-8 promoter activity and leads to IL-8 release. | |||||||||||||||||||||||||||||||||
| General Notes | 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use. 2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation. 3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value. 4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue. 5. Avoid cross-contamination of reagents and specimens to prevent erroneous results. 6. Avoid direct exposure to strong light during storage and incubation. 7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit. 8. Do not use expired products, and do not mix components with different product numbers and batches. 9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized. 10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures. |
|||||||||||||||||||||||||||||||||
| Storage Temp. | If the unopened kit is stored at 4°C, the shelf life is 6 months. | |||||||||||||||||||||||||||||||||
| Test Range | 0.31-20 ng/mL | |||||||||||||||||||||||||||||||||
| Applications | Tissue homogenates, cell lysates, and other biological fluids |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy
4.0 ★★★★★
Based on 1347 reviews
Sort
Product Reviews
★★★★★ 5
Great Mug Heat Press for Beginners and Small Businesses
Color: Blue
The HTVRONT mug heat press is very easy to use and works perfectly for sublimation mugs. It heats evenly, which helps the design transfer clearly and with vibrant colors. The temperature and time controls are simple to adjust, making it great for beginners as well as small business owners.
I’ve used it on 11 oz sublimation mugs and the results are consistent and professional. The machine feels sturdy, heats up fast, and saves time when making multiple mugs. Overall, it’s a reliable and affordable option for anyone starting or growing a sublimation business.
✅ Easy to use
✅ Even heat distribution
✅ Great print quality
✅ Ideal for sublimation mugs
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 27, 2026
★★★★★ 5
Nice product
Color: White
Awesome, easy to use and very consistent
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 11, 2026
★★★★★ 5
Love it. Its Great
Color: White
The HTVRONT Auto Tumbler Heat Press Machine is a specialized tool designed for sublimation projects, particularly for customizing tumblers, mugs, and other cylindrical items ranging from 10 to 30 ounces. It's an excellent choice for both hobbyists and small business owners looking to streamline their crafting process.
🔧 Key Features
Automatic Pressure Application: The machine automatically adjusts pressure based on the diameter of the item, ensuring consistent results without manual adjustments.
The How-To Home
Temperature and Timer Control: Offers a temperature range up to 390°F (200°C) and includes a timer function, allowing for precise control over the sublimation process.
Safety Features: Equipped with an emergency stop button and an auto shut-off feature after 15 minutes of inactivity, enhancing user safety.
Compact Design: Measures approximately 13 x 11 x 6.3 inches and weighs around 9.5 lbs, making it suitable for home studios or small workspaces.
Happiness is Homemade
Compatibility: Designed to accommodate items with a diameter of 2.95 to 3.35 inches, covering a wide range of tumbler and mug sizes.
🧠 Final Thoughts
The HTVRONT Auto Tumbler Heat Press Machine offers a blend of automation, safety, and versatility, making it a valuable addition to any crafting setup. Its user-friendly features and compact design cater to both beginners and experienced crafters, ensuring high-quality sublimation results.
Sources
Absolutely Love This Tumbler Press!
I’ve been using the HTVRONT Auto Tumbler Heat Press Machine for a few weeks now, and it has completely exceeded my expectations. The machine is incredibly easy to use—just set your temperature and timer, and it does all the hard work for you. I love that it automatically adjusts the pressure based on the tumbler size, which has saved me so much time and effort! The results are flawless every time. I’ve used it for several sublimation projects, and the colors come out vibrant and crisp. Plus, the safety features like the auto shut-off give me peace of mind while working. The compact design also fits perfectly in my small crafting space. I highly recommend this press to anyone looking to level up their sublimation game!
Durability is Great.
No smell
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 23, 2025
★★★★★ 4
So far, So good
Color: Blue
I have printed about 18 tumblers since purchasing this, all came out beautifully. It was delivered is great condition and is very easy to use. Just plug it in, set temperature and get your work started. No complaints thus far.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 9, 2026
★★★★★ 5
Great machine
Color: Blue
Love my press I have other presses and conventional ovens to sublimate, and this is by far a wonderful machine added to my craft room
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 9, 2026
recommand products
Monnit ALTA Industrial Wireless Pressure Meters - 300 PSIG
217.13
AMT 4294-010-01 - Impeller XSS 0.33 HP 1PH MBV -01
62.53
Platinum Tools 2" Batwing Clip HPH J-Hook, Size 32, Black. 25/Box
110.65
AMT 428B-030-95 - Volute Cover Kit
187.86
Monnit ALTA Accelerometer - G-Force Snapshot - Commercial AA Battery Powered
118.66