Description
2300/25-00 Bently Nevada 24-bit ADC MonitorBently Nevada 2300 25 00 Monitor with SPA Outputs (No Approvals) Manufacturer: Bently Nevada Part Number: 2300 25 00 Type: Monitor with SPA Outputs Approval: None (00) Made in: U. S. A. Key Specifications Power Input: 18 to 36 Vdc, maximum 7. 5 Watts Operating Temperature: 30C to +65C ( 22F to +149F) Storage Temperature: 40C to +85C ( 40F to +185F) Humidity: Up to 95% non condensing Vibration Limitation: 3g Weight: 1. 03 kg (2. 26 lbs) Mounting: Panel
Bently Nevada 2300/25-00 | Monitor with SPA Outputs (No Approvals)
Manufacturer: Bently Nevada | Part Number: 2300/25-00 | Type: Monitor with SPA Outputs | Approval: None (00) | Made in: U.S.A.
Key Specifications
- Power Input: 18 to 36 Vdc, maximum 7.5 Watts
- Operating Temperature: -30°C to +65°C (-22°F to +149°F)
- Storage Temperature: -40°C to +85°C (-40°F to +185°F)
- Humidity: Up to 95% non-condensing
- Vibration Limitation: 3g
- Weight: 1.03 kg (2.26 lbs)
- Mounting: Panel mount or DIN rail (adapter included)
Physical Dimensions
- Width: 127 mm (5 inches)
- Depth: 127 mm (5 inches)
- Height: 76.2 mm (3 inches)
- Compact design: Fits in standard industrial enclosures
Input Channels
- ICP Accelerometers: 0.2 Hz to 20 kHz bandpass filter, 5 to 1000 mV/g scale factor, 2 to 80 g peak full scale
- Velocity: 0.2 Hz to 20 kHz bandpass filter, 5 to 1000 mV/in/s scale factor, 0 to 50 in/s peak full scale
- Radial Vibration: 0.2 Hz to 20 kHz bandpass filter, 5 to 1000 mV/mil scale factor, 0 to 160 mil peak-peak full scale
- Thrust Channel: 5 to 1000 mV/mil scale factor range
- Process Variable Channel: Supports most units with default on temperature
Speed/Keyphasor Input
- Keyphasor transducers: Support multiple events per revolution
- Speed input: Up to 20 kHz
- Threshold voltage resolution: 0.1 Vdc
- RPM range: 1 to 120,000 (proximity), 1 to 60,000 (proximity switch), 200 to 120,000 (magnetic pickup)
Proximity Transducer Interface
- Supply Voltage: -22.8 to -25.2 Vdc
- Maximum Rated Current: 15 mA
- Short Circuit Current: 15.1 to 23.6 mA
- Accuracy: ±1% of full scale range
- Input Impedance (3-wire Voltage Mode): 10 kΩ
Measurement Accuracy
- Temperature Channel: ±1% of full scale range
- Proximity Transducer: ±1% of full scale range
- Independent 24-bit ADCs: On all input channels
- SPA Output Accuracy: High/Low AC ±1% of full-scale at 100 Hz, DC GAP ±0.5V
Outputs
- Buffered Outputs (BNC): 2 vibration outputs, 1 speed output
- Relays: Two dry-contact outputs, epoxy sealed, single pole double throw
- Relay Contact Life: 100,000 cycles at 5A, 250 Vac; 200,000 at 1A, 24 Vdc
- SPA Output (2300/25): High AC 8 Vpp, Low AC 1.6 Vpp, DC GAP 0 to -20 Vdc
- SPA Frequency Response: 10 Hz to 3000 Hz ±5%
Relay Specifications (Non-Hazardous Area)
- Type: Single pole, double throw, epoxy sealed
- Maximum switched contact voltage: 250 Vac / 250 Vdc
- Maximum breaking contact current: 6A at 250 Vac / 6A at 24 Vdc
- Maximum switched power: 1500VA AC / 150 Watts DC
Communications
- Ethernet: 10Base-T and 100Base-TX, conforms to IEEE802.3
- Connector: RJ-45 for 10Base-T/100Base-TX
- Maximum Cable Length: 100 meters (328 feet)
Data Storage
- Network disruption: Stores up to 5 alarm data captures
- Requires: System 1 Evolution 21.1 or newer, Firmware 3.2 or newer
- Trend Intervals: Pre-event 10 minutes at 1 second, 20 seconds at 100 milliseconds
- Spectrum/Waveform: Pre-event 2.5 minutes at 10 seconds
Battery Life (Real Time Clock)
- Powered: 38 years at 50°C (122°F)
- Un-powered: 12 years at 50°C (122°F)
Front Panel LEDs
- OK: Monitor operating properly
- Protection Fault: Hardware fault impacting alarm determination
- User Inhibit: Alarms/relays intentionally inhibited
- Bypass: User initiated bypass action
- Relay Status: Relays activated
- TX/RX: Ethernet status and remote communication
- SPEED/AUX Channel Status: Valid speed signal or operating correctly
- Alert LED: Any channel in alert state
- Danger LED: Any channel in danger state
LCD Display
- View machine speed readings
- View vibration measurement values
- View setpoints and configuration information
Contact Inputs
- 3 contact capabilities with input terminals for:
- Configuration lock
- Latched alarm/relay reset function
- Monitor bypass (activate 0 to 10 kΩ, de-activate 150 kΩ to infinite)
Button Inputs
- External button to reset latched alarm and relay
- One buried button provides 3 functions:
- Display monitor information
- LCD contrast adjustment
- Reset settings to default
Package Contents
- 2300/25-00 monitor with SPA outputs
- DIN rail mount assembly (adapter included)
- Monitor configuration software
- Installation manual
Shipping Information
- Weight: 1.5 kg (3.3 lb) packaged
- Packaging: Factory sealed box
- Carriers: FedEx, UPS, DHL (2-5 business days)
Frequently Asked Questions
-
Q: What is the difference between 2300/25-00 and 2300/25-02?
A: The 2300/25-00 has no hazardous area approvals (option 00). The 2300/25-02 has multiple explosive atmosphere certifications (ATEX/IECEx/CSA). Choose -00 for safe area installations only. -
Q: What is the SPA output?
A: SPA (Signal Processing Assembly) output provides High AC (8 Vpp), Low AC (1.6 Vpp), and DC GAP (0 to -20 Vdc) signals with frequency response of 10 Hz to 3000 Hz ±5% for external analysis. -
Q: How many channels does this monitor support?
A: The 2300/25-00 supports multiple channel types including ICP accelerometers, velocity, radial vibration, thrust, process variable, temperature, speed/Keyphasor, proximity switch, and magnetic pickup inputs. -
Q: What is the accuracy of the measurements?
A: The monitor features independent 24-bit ADCs on all input channels with ±1% of full scale range accuracy for most measurements. DC GAP accuracy is ±0.5V. -
Q: Does the monitor store data during network outages?
A: Yes. The 2300 can store up to 5 alarm data captures during network disruption between the 2300 and System 1. Requires System 1 Evolution 21.1 or newer and Firmware 3.2 or newer.
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy